Description
RTD with 7-pin plug and cable extension with 7 pin receptacle. Three wire dual element design with sheath diameter of 0.125″ (3.175mm) and Temperature range of -50°C to 200°C.
0.125″ (3.175mm) Dual Element RTD with extension cable
RTD with 7-pin plug and cable extension with 7 pin receptacle. Three wire dual element design with sheath diameter of 0.125″ (3.175mm) and Temperature range of -50°C to 200°C.
0.250″ (6.35mm) sheath diameter general purpose thermocouple plain sheath with one diameter for entire sheath length.
Sensor type | Thermocouple (Special Limits) |
Temperature range | -200°C to 1260°C (-328°F to 2300°F) |
Sensor style | Hand-held |
Sheath diameter | 0.250" |
Immersion depth | Variable |
Process connection | None |
Head connection | None |
Spring loaded for thermowell | No |
Wire termination | Cable |
Hazardous ratings | None |
0.250″ (6.35mm) spring-loaded platinum RTD for thermowell applications. Offered as a bare sensor or with a thermowell. Hazardous ratings are available.
Sensor type | RTD (PT100) |
Temperature range | -50 to 200 C (-58 to 392 F) |
Sensor style | Indirect Immersion |
Sheath diameter | 0.250" |
Immersion depth | fixed |
Process Connection | Threaded/Tri-clamp/Socket weld/Flanged/Weld in/Van Stone |
Head connection | NPT |
Spring loaded for thermowell | Yes |
Wire termination | Head |
Hazardous rating | Optional |
0.250″ (6.35mm) sheath diameter platinum RTD designed for variable immersion. Hazardous ratings are available.
Sensor type | RTD (Pt100) |
Temperature range | -196 to 500 C (-320.8 to 932 F) |
Sensor style | Direct Immersion |
Sheath diameter | 0.25", 0.188" |
Immersion depth | Variable |
Process Connection | None |
Head connection | NPT |
Spring loaded for thermowell | No |
Wire termination | Head |
Hazardous rating | Optional |
0.250″ (6.35mm) sheath diameter spring-loaded platinum RTD with bayonet fitting for thermowell applications. Hazardous ratings are available.