S40

Heavy-duty, 0.500″ (12.7mm) to 0.250″ (6.35mm), direct immersion sanitary sensor. Available as an RTD or thermocouple.

Heavy-duty defines the Model S40. The 1/2″ diameter stem and 1/4″ diameter tip section are designed to withstand high velocity and/or viscous fluids while still providing a fast 3.5 second time constant required for high-temperature short time (HTST) pasteurization processes.

Case Study https://burnsengineering.com/wp-content/uploads/2021/03/A130412-high-Vibration-Sanitary-Solution-Series-300.pdf

Series S Standard Spec Sheet

https://burnsengineering.com/wp-content/uploads/2021/05/Series-S.pdf

Sensor typeRTD (Pt100) or Thermocouple
Temperature range-50 to 200 C (-58 to 392 F)
Sensor styleDirect Immersion
Sheath diameter0.500"
Immersion depthFixed
Process connection Hygienic Ferrule
Head connectionM12, 0.5" NPT, NPSM, 3/8" UNF
Spring loaded for thermowellNo
Wire terminationCable or Head
Hazardous ratingNone
Configure Part Application Notes