Description
Precision platinum wire RTD is used for monitoring and controlling the temperature of disposable bioreactor bag systems. Features a variety of optional process connections.
Precision platinum wire RTD is used for monitoring and controlling the temperature of disposable bioreactor bag systems.
Precision platinum wire RTD is used for monitoring and controlling the temperature of disposable bioreactor bag systems. Features a variety of optional process connections.

The SRS is designed for use in the SNR housing and is available as either an RTD or thermocouple.
| Sensor type | RTD (Pt100) or Thermocouple |
| Temperature range | -50 to 200 C (-58 to 392 F) |
| Sensor style | Indirect Immersion |
| Sheath diameter | None |
| Immersion depth | Fixed |
| Process connection | None |
| Instrument connection | Hygienic Ferrule |
| Spring loaded for thermowell | No |
| Wire termination | Cable, Head |
| Hazardous rating | None |

Our standard RTD autoclave sensor available in 0.250″ (6.35mm), or 0.188″ (4.7625mm) diameter sheath.
| Sensor type | RTD (Pt100) |
| Temperature range | -50 to 200 C (-58 to 392 F) |
| Sensor style | Direct Immersion |
| Sheath diameter | 0.250", 0.188" |
| Immersion depth | Fixed |
| Process connection | None |
| Instrument connection | None |
| Spring loaded for thermowell | No |
| Wire termination | Cable |
| Hazardous rating | None |

The SAL load probe RTD sensor is available in either straight or with a 90-degree bend and 0.125″ (3.175mm) diameter sheath.
| Sensor type | RTD (Pt100) |
| Temperature range | -50 to 135 C (-58 to 275 F) |
| Sensor style | Direct Immersion |
| Sheath diameter | 0.125" |
| Immersion depth | Fixed |
| Process connection | None |
| Instrument connection | None |
| Spring loaded for thermowell | No |
| Wire termination | Cable |
| Hazardous rating | None |

Extreme-duty autoclave RTD with an armored cable to withstand harsh environments and handling.
| Sensor type | RTD (Pt100) |
| Temperature range | -50 to 200 C (-58 to 392 F) |
| Sensor style | Direct Immersion |
| Sheath diameter | 0.250", 0.375" |
| Immersion depth | Fixed |
| Process connection | Hygienic ferrule |
| Instrument connection | None |
| Spring loaded for thermowell | No |
| Wire termination | Cable |