• My Account
  • Register
  • Sign In
  • Products
    • Sanitary
    • Industrial
    • Metrology
    • Transmitters
    • Connection Heads
    • Calibration
    • Custom Products
  • Industries
    • Aerospace
    • Biotechnology
    • Brewing
    • Chemical
    • Cold Chain Monitoring
    • Dairy
    • Environmental
    • Food & Beverage
    • HVAC
    • Life Sciences
    • Manufacturing
    • Metrology
    • Oil & Gas
    • Pharmaceutical
  • Services
    • Calibration
  • Resources
    • Manuals
    • Technical Papers
    • Application Notes
    • FAQ
    • Industry Links
    • Product Videos and Tutorials
    • RTDology Temperature Training
    • Certificates
    • Business Forms
  • About Burns
    • About Burns
    • Careers
  • Contact
    • Contact Us
    • Representatives
  • Products
    • Sanitary
    • Industrial
    • Metrology
    • Transmitters
    • Connection Heads
    • Calibration
    • Custom Products
  • Industries
    • Aerospace
    • Biotechnology
    • Brewing
    • Chemical
    • Cold Chain Monitoring
    • Dairy
    • Environmental
    • Food & Beverage
    • HVAC
    • Life Sciences
    • Manufacturing
    • Metrology
    • Oil & Gas
    • Pharmaceutical
  • Services
    • Calibration
  • Resources
    • Manuals
    • Technical Papers
    • Application Notes
    • FAQ
    • Industry Links
    • Product Videos and Tutorials
    • RTDology Temperature Training
    • Certificates
    • Business Forms
  • About Burns
    • About Burns
    • Careers
  • Contact
    • Contact Us
    • Representatives
Click Here to Schedule An Appointment

Product Categories

  • Sanitary
  • Industrial
  • Metrology
  • Transmitters
  • Connection Heads
  • Calibration

Showing 1–12 of 13 results

  • 19A Head with Indicator

    19A Head with Indicator

    Explosion proof aluminum body with loop power and integrated temperature indicator.

    Configure Part Quick View
    x

    19A Head with Indicator 19A Head with Indicator

    19A Head with Indicator
    Explosion proof aluminum body with loop power and integrated temperature indicator.
    MaterialAluminum
    Hazardous area ratingYes
    IndicatorYes (loop powered)
    Configure Part More Information
  • 20P Head with Indicator

    20P Head with Indicator

    Plastic bodied connection head with integrated temperature indicator and loop power.

    Configure Part Quick View
    x

    20P Head with Indicator 20P Head with Indicator

    20P Head with Indicator
    Plastic bodied connection head with integrated temperature indicator and loop power.
    MaterialPlastic
    Hazardous area ratingNo
    IndicatorYes (loop powered)
    Configure Part More Information
  • 22A Head with Indicator

    22A Head with Indicator

    Explosion proof aluminum body with battery power and integrated temperature indicator.

    Configure Part Quick View
    x

    22A Head with Indicator 22A Head with Indicator

    22A Head with Indicator
    Explosion proof aluminum body with battery power and integrated temperature indicator.
    MaterialAluminum (Blue painted)
    Hazardous area ratingYes
    IndicatorYes (battery powered)
    Configure Part More Information
  • 23P Head with Indicator

    23P Head with Indicator

    Plastic bodied connection head with integrated temperature indicator and battery power.

    Configure Part Quick View
    x

    23P Head with Indicator 23P Head with Indicator

    23P Head with Indicator
    Plastic bodied connection head with integrated temperature indicator and battery power.
    MaterialPlastic
    Hazardous area ratingNo
    IndicatorYes (battery powered)
    Configure Part More Information
  • 24S Head with Indicator

    24S Head with Indicator

    Stainless steel bodied enclosure with integrated battery powered temperature indicator.

    Configure Part Quick View
    x

    24S Head with Indicator 24S Head with Indicator

    24S Head with Indicator
    Stainless steel bodied enclosure with integrated battery powered temperature indicator.
    MaterialStainless steel
    Hazardous area ratingYes
    IndicatorYes(battery powered)
    Configure Part More Information
  • T75 Head with Indicator

    T75 Head with Indicator

    Transmitter w/ Indicating Head. HART 5 & 7. Hazardous Location Approved

    Configure Part Quick View
    x

    T75 Head with Indicator T75 Head with Indicator

    T75 Head with Indicator
    Transmitter w/ Indicating Head. HART 5 & 7. Hazardous Location Approved
    MaterialAluminum
    Hazardous area ratingYes
    IndicatorYes
    Configure Part More Information
  • E01

    E01

    0.250″ (6.35mm) sheath diameter cut-to-length platinum RTD is available with several mounting options.

    Configure Part Quick View
    x

    E01 E01

    E01
    0.250" (6.35mm) sheath diameter cut-to-length platinum RTD is available with several mounting options.
    Sensor typeRTD (PT100)
    Temperature range-50°C to 200°C (-58°F to 392°F)
    Sensor styleDirect Immersion, Indirect Immersion
    Sheath diameter0.250" (6.35mm)
    Immersion depthfixed/variable
    Process Connection Compression, 0.50" NPT
    Instrument connection0.50" NPT, K style (twist lock) for #3 or #5 heads, or C style for other heads
    Spring loaded for thermowellOptional
    Wire terminationCable, Head,
    Hazardous ratingNone
    Configure Part More Information
  • E02

    E02

    0.250″ (6.35mm) sheath diameter segmented platinum RTD available with several mounting options.

    Configure Part Quick View
    x

    E02 E02

    E02
    0.250" (6.35mm) sheath diameter segmented platinum RTD available with several mounting options.
    Sensor typeRTD (Pt100)
    Temperature range-50°C to 200°C (-58°F to 392°F)
    Sensor styleDirect Immersion, Indirect Immersion, Hand-held, Laboratory-Calibration
    Sheath diameter.080" (2.0mm), 0.125" (3.175mm), 0.188" (4.76mm), 0.250' (6.35mm), 0.375" (9.52mm)
    Immersion depthfixed/variable
    Process Connection Compression, Threaded, Hygienic Ferrule, Socket weld, Flanged, Weld in, Van Stone, None
    Instrument connectionHygienic Ferrule, NPT, No exposed threads (NPSM)
    Spring loaded for thermowellOptional
    Wire terminationCable, Head, Both
    Hazardous ratingNone
    Configure Part More Information
  • E03

    E03

    0.250″ (6.35mm) sheath diameter flexible, armored cable RTD or thermocouple.

    Configure Part Quick View
    x

    E03 E03

    E03
    0.250" (6.35mm) sheath diameter flexible, armored cable RTD or thermocouple.
    Sensor typeRTD (Pt100) or Thermocouple
    Temperature range-50°C to 200°C (-58°F to 392°F)
    Sensor styleIndirect Immersion
    Sheath diameter0.250" (6.35mm)
    Immersion depthVariable
    Process connection Thermowell
    Instrument connectionHygienic Ferrule, NPT, No exposed threads (NPSM)
    Spring loaded for thermowellYes
    Wire terminationCable, Head
    Hazardous ratingNone
    Configure Part More Information
  • T55

    T55

    Loop powered two wire transmitter for head mounting. HART 5 programmable.

    Configure Part Quick View
    x

    T55 T55

    T55
    Loop powered two wire transmitter for head mounting. HART 5 programmable.
    TypeProgrammable
    StyleHead Mounted
    Sensor inputRTD, Thermocouple
    Number of sensor inputs1
    Output4-20mA
    Communication protocolHART 5
    Local indicatorNo
    WirelessNo
    Configure Part More Information
  • T57

    T57

    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 or 7 programmable.

    Configure Part Quick View
    x

    T57 T57

    T57
    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 or 7 programmable.
    TypeProgrammable
    StyleHead Mounted
    Sensor inputRTD, Thermocouple
    Number of sensor inputs1
    Output4-20mA
    Communication protocolHART 7
    Local indicatorNo
    WirelessNo
    Configure Part More Information
  • T65

    T65

    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 programmable.

    Configure Part Quick View
    x

    T65 T65

    T65
    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 programmable.
    TypeProgrammable
    StyleHead Mounted
    Sensor inputRTD, Thermocouple
    Number of sensor inputs1
    Output4-20mA
    Communication protocolHART 5
    Local indicatorNo
    WirelessNo
    Configure Part More Information
  • 1
  • 2
  • →

GET IN TOUCH

Click below to schedule a call with one of our product experts, or fill out the form and we’ll reach out to you.

SCHEDULE APPOINTMENT
  • Max. file size: 50 MB.

SCHEDULE APPOINTMENT

Products

  • Sanitary
  • Industrial
  • Metrology
  • Transmitters
  • Connection Heads
  • Custom Products

Services

  • Calibration Services

Resources

  • About Us
  • Manuals
  • Technical Papers
  • Application Notes
  • FAQ
  • Industry Links

Customer Info

  • My Quote Request
  • Serial Number Look Up
  • Order Status
  • Certificates and Declarations
  • Component Certificates
  • Business Forms

Contact

  • Sign In
  • Register
  • Request Information
  • Representatives
  • info@burnsengineering.com
  • 952-935-4400
  • 9675 W 76th ST STE 100, Eden Prairie, MN 55344-3756
Facebook-f Linkedin-in
  • Sitemap
  • Sign In
  • Register
  • Contact
  • info@burnsengineering.com
  • 952-935-4400