Description
The SRS is designed for use in the SNR housing and is available as either an RTD or thermocouple.
The SRS is designed for use in the SNR housing and is available as either an RTD or thermocouple.
The SRS is designed for use in the SNR housing and is available as either an RTD or thermocouple.
Dampening thermowell sleeves are designed with special dampening characteristics for specific applications.
Mounting Style | Adapter Sleeve |
Stem Style | NA |
Sensor Connection | NA |
0.250″ (6.35mm) diameter RTD sanitary sensor with Ingold® port and 15º angle fitting.
Sensor type | RTD (Pt100) or Thermocouple |
Temperature range | -50 to 200 C (-58 to 392 F) |
Sensor style | Direct Immersion |
Sheath diameter | 0.250" |
Immersion depth | Fixed |
Process connection | Ingold |
Instrument connection | 0.5" NPT, NPSM, 3/8" UNF |
Spring loaded for thermowell | No |
Wire termination | Cable or Head |
Hazardous rating | None |
0.125″ (3.175mm) direct immersion sanitary sensor. Available as an RTD or thermocouple.
Sensor type | RTD (Pt100) or Thermocouple |
Temperature range | -50 to 200 C (-58 to 392 F) |
Sensor style | Direct Immersion |
Sheath diameter | 0.125" |
Immersion depth | Fixed |
Process connection | Hygienic Ferrule |
Instrument connection | M12, 0.5" NPT, NPSM, 3/8" UNF |
Spring loaded for thermowell | No |
Wire termination | Cable or Head |
Hazardous rating | None |
Sanitary thermowells available with tapered, reduced or small diameter tips.
Mounting style | Hygienic ferrule |
Stem Style | Tapered |
Sensor Connection | 0.50" NPT |