Description
0.250″ (6.35mm) diameter 3.5 to 6 inches in length with a Teflon insulated cable.
*Note, a bored through 0.25″ compression fitting may be added.
Precision freezer temperature sensor for monitoring or control. 0.250″ (6.35mm) diameter
0.250″ (6.35mm) diameter 3.5 to 6 inches in length with a Teflon insulated cable.
*Note, a bored through 0.25″ compression fitting may be added.
The SNR sensor housing features a removable RTD or thermocouple and a variety of sanitary connection options.
Sensor type | RTD (Pt100) orThermocouple |
Temperature range | -50 to 200 C (-58 to 392 F) |
Sensor style | Non |
Sheath diameter | None |
Immersion depth | Fixed |
Process connection | Hygienic Ferrule, Weld-In |
Instrument connection | 0.50" NPT, NPSM, 3/8" UNF |
Spring loaded for thermowell | No |
Wire termination | Cable, Head |
Hazardous rating | None |
The SFM is available in either RTD or thermocouple and is typically installed in vessels through the wall and flush with the inner surface.
Sensor type | RTD (Pt100) or Thermocouple |
Temperature range | -50 to 200 C (-58 to 392 F) |
Sensor style | Direct Immersion |
Sheath diameter | N/A |
Immersion depth | Fixed |
Process connection | Weld in |
Head connection | M12, 0.5 NPT, NPSM, 3/8 UNF |
Spring loaded for thermowell | No |
Wire termination | Cable, Head |
Hazardous rating | None |
0.125″ (3.175mm) spring-loaded sanitary sensor for thermowell applications. Available as an RTD or thermocouple.
Sensor type | RTD (Pt100) or Thermocouple |
Temperature range | -50 to 200 C (-58 to 392 F) |
Sensor style | Indirect Immersion |
Sheath diameter | 0.125" |
Immersion depth | Fixed |
Process connection | 0.5" NPT, NPSM |
Instrument connection | Hygienic Ferrule |
Spring loaded for thermowell | Yes |
Wire termination | Cable or Head |
Hazardous rating | None |
0.250″ (6.35mm) spring-loaded sanitary sensor for thermowell applications. Available as an RTD or thermocouple.
Sensor type | RTD (Pt100) or Thermocouple |
Temperature range | -50 to 200 C (-58 to 392 F) |
Sensor style | Indirect Immersion |
Sheath diameter | 0.250" |
Immersion depth | Fixed |
Process connection | 0.5" NPT, NPSM |
Instrument connection | Hygienic Ferrule |
Spring loaded for thermowell | Yes |
Wire termination | Cable or Head |
Hazardous rating | None |