• My Account
  • Register
  • Sign In
  • Products
    • Sanitary
    • Industrial
    • Metrology
    • Transmitters
    • Connection Heads
    • Calibration
    • Custom Products
  • Industries
    • Aerospace
    • Biotechnology
    • Brewing
    • Chemical
    • Cold Chain Monitoring
    • Dairy
    • Environmental
    • Food & Beverage
    • HVAC
    • Life Sciences
    • Manufacturing
    • Metrology
    • Oil & Gas
    • Pharmaceutical
  • Services
    • Calibration
  • Resources
    • Manuals
    • Technical Papers
    • Application Notes
    • FAQ
    • Industry Links
    • Product Videos and Tutorials
    • RTDology Temperature Training
    • Certificates
    • Business Forms
  • About Burns
    • About Burns
    • Careers
  • Contact
    • Contact Us
    • Representatives
  • Products
    • Sanitary
    • Industrial
    • Metrology
    • Transmitters
    • Connection Heads
    • Calibration
    • Custom Products
  • Industries
    • Aerospace
    • Biotechnology
    • Brewing
    • Chemical
    • Cold Chain Monitoring
    • Dairy
    • Environmental
    • Food & Beverage
    • HVAC
    • Life Sciences
    • Manufacturing
    • Metrology
    • Oil & Gas
    • Pharmaceutical
  • Services
    • Calibration
  • Resources
    • Manuals
    • Technical Papers
    • Application Notes
    • FAQ
    • Industry Links
    • Product Videos and Tutorials
    • RTDology Temperature Training
    • Certificates
    • Business Forms
  • About Burns
    • About Burns
    • Careers
  • Contact
    • Contact Us
    • Representatives
Click Here to Schedule An Appointment
Transmitters

Product Categories

  • Sanitary
  • Industrial
  • Metrology
  • Transmitters
  • Connection Heads
  • Calibration

Transmitters

  • Analog
  • Programmable
  • Programmable HART
  • Programming Modules
  • Rosemount®

Programmable HART

  • All
  • Head Mount
  • Loop Power
  • Programmable HART
  • Rail Mounted
  • RTD
  • Thermocouple

Showing all 5 results

  • T75 Head with Indicator

    T75 Head with Indicator

    Transmitter w/ Indicating Head. HART 5 & 7. Hazardous Location Approved

    Configure Part Quick View
    x

    T75 Head with Indicator T75 Head with Indicator

    T75 Head with Indicator
    Transmitter w/ Indicating Head. HART 5 & 7. Hazardous Location Approved
    MaterialAluminum
    Hazardous area ratingYes
    IndicatorYes
    Configure Part More Information
  • T55

    T55

    Loop powered two wire transmitter for head mounting. HART 5 programmable.

    Configure Part Quick View
    x

    T55 T55

    T55
    Loop powered two wire transmitter for head mounting. HART 5 programmable.
    TypeProgrammable
    StyleHead Mounted
    Sensor inputRTD, Thermocouple
    Number of sensor inputs1
    Output4-20mA
    Communication protocolHART 5
    Local indicatorNo
    WirelessNo
    Configure Part More Information
  • T57

    T57

    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 or 7 programmable.

    Configure Part Quick View
    x

    T57 T57

    T57
    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 or 7 programmable.
    TypeProgrammable
    StyleHead Mounted
    Sensor inputRTD, Thermocouple
    Number of sensor inputs1
    Output4-20mA
    Communication protocolHART 7
    Local indicatorNo
    WirelessNo
    Configure Part More Information
  • T65

    T65

    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 programmable.

    Configure Part Quick View
    x

    T65 T65

    T65
    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 programmable.
    TypeProgrammable
    StyleHead Mounted
    Sensor inputRTD, Thermocouple
    Number of sensor inputs1
    Output4-20mA
    Communication protocolHART 5
    Local indicatorNo
    WirelessNo
    Configure Part More Information
  • T67

    T67

    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 or 7 programmable.

    Configure Part Quick View
    x

    T67 T67

    T67
    Loop powered RTD or thermocouple transmitter for DIN rail mounting. HART 5 or 7 programmable.
    TypeProgrammable
    StyleHead Mounted
    Sensor inputRTD, Thermocouple
    Number of sensor inputs1
    Output4-20mA
    Communication protocolHART 7
    Local indicatorNo
    WirelessNo
    Configure Part More Information

GET IN TOUCH

Click below to schedule a call with one of our product experts, or fill out the form and we’ll reach out to you.

SCHEDULE APPOINTMENT
  • Max. file size: 50 MB.

SCHEDULE APPOINTMENT

Products

  • Sanitary
  • Industrial
  • Metrology
  • Transmitters
  • Connection Heads
  • Custom Products

Services

  • Calibration Services

Resources

  • About Us
  • Manuals
  • Technical Papers
  • Application Notes
  • FAQ
  • Industry Links

Customer Info

  • My Quote Request
  • Serial Number Look Up
  • Order Status
  • Certificates and Declarations
  • Component Certificates
  • Business Forms

Contact

  • Sign In
  • Register
  • Request Information
  • Representatives
  • info@burnsengineering.com
  • 952-935-4400
  • 9675 W 76th ST STE 100, Eden Prairie, MN 55344-3756
Facebook-f Linkedin-in
  • Sitemap
  • Sign In
  • Register
  • Contact
  • info@burnsengineering.com
  • 952-935-4400